Mcquay model number tonnage.

This McQuay model WMC Centrifugal water chiller is a complete, self-contained, automatically controlled, fluid-chilling unit featuring dual Oil-Free Centrifugal Magnetic Bearing technology. This used 2006 McQuay 290 Ton Water-Cooled Chiller is located in our facility in Dallas, Texas and is ready to ship to your location. NEVER CHANGE OIL IN YOUR CHILLER AGAIN!!! McQuay WMC: Brochure McQuay ...

Mcquay model number tonnage. Things To Know About Mcquay model number tonnage.

Please consult McQuay Sales Representative for specific availability. McQuay WSHP Product Nomenclature WCMS 1009 E Z Product Category W = WSHP Product Identifier See box below Design Series 1 = A Design 2 = B Design 3 = C Design 4 = D Design 5 = E Design Nominal Capacity 007 = 7,000 009 = 9,000 012 = 12,000 015 = 15,000 019 = …York HVAC Model Number Name Decoding Guide. YORK HVAC EQUIPMENT NOMENCLATURE GUIDE - DECODE the PRODUCT NUMBER found on the EQUPMENT DATA TAG. CLICK ANYWHERE on THIS PAGE to RETURN to YORK HVAC Information at InspectApedia.com. z Z z a z zoa g z Z 33 00 < z 88 o o z < e a 2 z o. W x.For example, a 1000 ton dual will have two nominal 500 ton compressors mounted. As the chiller unloads from 100% load, one compressor shuts off at approximately 600 tons (60% of full load). Only one compressor is required to circulate enough refrigerant to meet the load.Used 22 ton McQuay chiller, model ALR022C, air cooled, R22 refrigerant, 25 hp compressor, air cooled, 460 volt, serial# 5ZC8505602, built 1994. ... AccuChiller chiller, Model LP2R2504, serial number 10555010708, includes (2) Trane compressors, Model numbers CSHA100K0E00 and CSHA150K0E00, 10 HP and 15 HP, serial number 07134KD91A.

This supplement only applies to RGS180 units when there is "B" in the 9th position of the Model Number, as shown in the Model Number Nomenclature diagram below. Check the Unit Nameplate (see Figs. 1 & 2). If there is not a "B" in the 9th position of the model number discard this document. MODEL NOMENCLATURE MODEL SERIES R G S 1 8 0 H F ...Find Us. McQuay Air-conditioning Limited (+852) 2893 6261; Unit 901~905, 9/F,Elite Centre, 22 Hung To Road, Kwun Tong, Kowloon,Hong Kong

HVAC Technician: Steven S. McQuay - WSC087-BAAA Water-Cooled (Semi-Hermetic) - 460V / 480V / 3-Phase / 60Hz - 400 Ton Capacity. Ask Your Own HVAC Question. WSC087-BAABC is the model number.Here the 3/4 indicates a 3 to 4 ton drive. There are 400 CFM (Cubic Feet Per Minute) of airflow per ton of cooling. The capability of air movement of this example furnace is 1200 to 1600 cubic feet per minute of air. ... Condensing Unit Model Number Breakdown. Different parts of the model number mean different things. Take a 10AC36-1P for ...

Ford cars come in all shapes and price ranges. See pictures and learn about the specs, features and history of Ford car models. Advertisement Ford models come in all shapes and pri...We would like to show you a description here but the site won't allow us.McQUAY CENTRIFUGAL OPERATING LOG. .23 McQUAY SERVICE PROGRAMS 24.17, 18 18 18 18 18 18 19 19 INTRODUCTION GENERAL DESCRIPTION The McQuay Model PEH Centrifugal Water Chillers are com-plete, self-contained, automatically controlled water chilling units. Each unit is completely assembled and factory tested prior to shipment.The Raspberry Pi Foundation released a new model of the Raspberry Pi today. Dubbed the A+, this one's just $20, has more GPIO, a Micro SD slot, and is a lot smaller than the previo...Click the PDF file below to view information on the Aquasnap Model Number Nomenclature / Chiller Model Number Chart. Aqua_snap_model_numbers.jpg. Prev: 1.10 Aquasnap Model Number Nomenclature Chart ; Next: ... 1.2 Governair Chillers Model Number Nomenclature; 1.3 McQuay ABZ Series; 1.4 Smardt Air Cooled Chillers; 1.5 Smardt Water Cooled Chillers;

Model Number. WCAE= Concealed Ceiling WSHP, Alerton control, Extended Range. WCAS= Concealed Ceiling WSHP, Alerton control, Standard Range. ... Please contact …

With the WMC capacity range of 110 to 175 tons, it falls into two ASHRAE 90.1 efficiency requirements - below 150 tons and 150 tons & larger. Below 150 tons, the standard requires a full load and IPLV of 0.703 kW/ton (5.0 C.O.P.). The WMC chiller will easily meet these requirements.

Daikin RoofPak applied packaged rooftop systems, from 15 to 150 tons, are the ideal solution for your one to eight-story building projects. Available in air-cooled and evaporative-cooled models, they combine the lower installation costs and interior space savings of a roof-mounted system with the operating and maintenance efficiencies of ... Daikin McQuay Path nder Air Cooled Chiller Screw Compressor 2 Circuit Model: AWS Sizes: 280- 350 Vintage: A R134a 50 Hz Replacement Parts List No. 700014200 New 08/09 To nd your McQuay parts distributor, call 1-800-377-2787 or visit www .mcquay. comThe date of production/manufacture or age of AAF brand HVAC equipment can be determined from the serial number located on the data plate. Note: Traditional heating and cooling systems no longer manufactured under AAF or AAF-McQuay brand names. Parent Company: AAF International and AAF-Flanders, a subsidiary company of Daikin Industries.R = 208-230/1/60 62 = 5 Vintage * 10 SEER Size 036, 049 and 060 only. **10 SEER Size 060 only. Table 1: Unit Nameplate Model Number Identifier Unit Nameplate McQuay Model Number CKL18-1L ACU018ARAY CKL24-1L ACU024ARAY CKL30-1L ACU030ARAY CKL36-1L... Page 4: Introduction Replacement Parts substantial fines. McQUAY CENTRIFUGAL OPERATING LOG. .23 McQUAY SERVICE PROGRAMS 24.17, 18 18 18 18 18 18 19 19 INTRODUCTION GENERAL DESCRIPTION The McQuay Model PEH Centrifugal Water Chillers are com-plete, self-contained, automatically controlled water chilling units. Each unit is completely assembled and factory tested prior to shipment.

Model Number Reference Guide. Challenger 3000 Self-Contained Air Conditioning System - Technical Data Manual ... McQuay Website. Air-Cooled Chillers. ALS - Air-Cooled Rotary Screw Chiller - 070A through 425A - Installation, Operation and Maintenance Manual - June 1999 ... 55 to 200 Ton - Installation, Operation, Maintenance - 2016.The label/tag has faded all I have on file is the model number and the serial number, make. Question Posted By Francisco the Building Engineer on May 3, 2011. Refer to the manufacturer’s website for their HVAC nomenclature of the model number and serial numbers and how those numbers correspond to the tonnage and other technical data.Air Handlers. Subcategory. Air Handlers. View All. Used McQuay approximately 15 - 20 Ton, 2000 to 6000 CFM. model RDS708BY air conditioning unit. Overall Dimensions 68" wide x 52" high. 5 HP Evaporator fan motor. All loads 460 volt. S/N FB0402030023603. Stock#20667.Complete each section bottom and top before attaching additional sections. McQuay IM 672-3... Page 6 5/16"-18 × 1" bolt. Once the bolt is in place, secure the bracket to the adjoining section with a 1/4 × 1" drill screw. Repeat the same procedure on both corners of the unit.Enfinity vertical floor-mounted water source heat pumps (WSHP), from 3/4 to 6 tons in left and right hand configurations, are designed for high efficiency, individually-zoned comfort control in office buildings, schools, hotels, assisted living dwellings, manufacturing facilities, and other commercial buildings.

Hetecho Engineers. Tilpat, Ghaziabad, Uttar Pradesh. View Number. Chvac Machinery Solutions Private Limited - Offering Mcquay Chiller, Capacity: 100-1500 TON at Rs 500000 in Ghaziabad, Uttar Pradesh. Get Water Chillers at lowest price | ID: 21748827133.MicroTech SmartSource Controller with BACnet®Communication Module. Daikin water source heat pumps are available with a BACnet MS/TP communication module that is designed to communicate over a BACnet MS/TP communications network to a building automation system (BAS) . It can be factory or field-installed.

McQuay Air Conditioning plant with over 450,000 square feet of manufacturing space - located in Auburn, New York Horizontal (Ceiling) Water Source Heat Pumps – Sizes 007-070 (1/2 to 6 Tons) Model CRH (Standard Range: 55°F to 110°F) Model CRW (Extended Range/Geothermal: 25°F to 110°F) More than 40 years ago, McQuay designed the first A comprehensive guide to McQuay replacement. Find the equivalent Islandaire model easily for a Perfect Fit! Skip to content. Customer Account; Connect with Islandaire: Home; ... Islandaire Model: McQuay® K, EK and RK Series: 13 15/16: 36: McQuay® Type EA, RS & ES Series: 16 3/8: 44 7/8: McQuay® C/EC Series: 27 3/8: 54 1/2: McQuay® EB Series ...McQuay 6- to 10-ton horizontal units have a common cabi-net size and common water, condensate, and duct connection locations for easier and more efficient installation. The cabinet is constructed of unpainted, G-60 galvanized steel. Large panels provide access to the fan/motor compart-ment and the compressor/control compartment. The interiors ofThe optimum model can be selected from an extensive product lineup for medium- to large-scale facilities for use in a variety of applications. Versatility. Daikin delivers energy efficiency to a wide range of process cooling applications with a lineup featuring a full range of capacities for all conditions and cooling requirements. ...Troubleshooting Refrigeration Circuit. 25. Typical Refrigeration Cycles. 26. General Maintenance. 27. Advertisement. Mcquay Enfinity CCH series Pdf User Manuals. View online or download Mcquay Enfinity CCH series Installation & Maintenance Data.Model Line. Model Line 10 Easy Maintenance Tips. View Resource . A Parts Map - CXVB Evaporative Condenser. View Resource . A Parts Map - FXV Closed Circuit Cooling Tower ... The serial number will be spray painted on your unit and/or on a label by the access door. For units purchased after 2000 it will start with a U. Model Number.

Available from 300 to 1200 tons, single compressor centrifugal chillers offer excellent full-load and part-load performance for increased energy savings and an excellent life cycle return on your investment. Using R-134a or R513A refrigerant, these chillers easily integrate with building automation systems, are seismic compliant, quiet and have ...

McQuay International Re-Manufactured Screw Compressor. Model: SAL155QA10DA. Capacity: 60 tons using Freon, only. ... 60 Ton. Sold Out. Roll over image to Zoom OR Click for full Gallery (images, video, data sheets) ... McQuay; Model: SAL155QA10DA; Serial Number: 55GR7061-10; Package Details. Screw Compressor Details. Micro Panel Details.

MODEL CODE A C Z XXX B " Air-Cooled Condensing Unit Scroll Compressor Vinta ge Nominal Tons ©2007 McQuay International. Illustrations and data cover the McQuay International product at the time of publication and we reserve the right to make changes in design and construction at anytime without notice. ™® The following are trademarks ormodel type w = water to water heat pump configuration unit size 036 - e,f,g,h revision level a = current 036 b = current 060, 120, 170, 340 voltage controls cabinet insulation 1 = extended range hot water generator options (tmw036-120 only) c = copper source water coil options n = cupro-nickel c = copperA ton of air conditioning equals 12,000 BTU, and 48 divided by 12 equals 4, so the data plate below indicates the system is 4 tons. Here's a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. And this is another one that is 3-1/2 tons.This Used McQuay 100 Ton Air Cooled Chiller has been inspected and is located in our facility in Bridgeport, Tx. This machine has sold. View more machines. McQuay AGZ: Product Document ... Model Number: AGZ100; Year: 2011; 100 Tons Nominal Cooling; 460V/3Ph/60Hz; Refrigerant: R-410a;The subbase for the Suite II series hydronic heat model is 8" high with a front air intake grille. Leveling legs are supplied with each subbase that allow for an additional 1" adjustment. The standard subbase requires a minimum of 4-3 /8" from the front edge of the wall sleeve to the finished wall.McQuay R-410A condensing units are available with EERs that exceed ASHRAE 90.1-2004. R-407C inevitably forces the unit to be significantly less efficient or more expensive, while R-410A reduces energy costs. R-410A refrigerant components are always evenly mixed, which is not true for R-407C.GROUP mcQUAY..P&Af'EX Inc. t36001ndustriaiParkB!vd.P.O.Box1551,Minneapolis,Mn.55440 . ND ... Available in three model types for horizontal and vertical unit arrangements: LSL VERTICAL UNIT ... -----NUMBER OF FANS IN STANDARD UNIT LYF-VENTILATING FAN SECTION LHD …Download 184 McQuay Heat Pump PDF manuals. User manuals, McQuay Heat Pump Operating guides and Service manuals. burner model number, minimum/maximum input, maximum temperature rise, and minimum CFM. On units that utili ze the tandem scroll compressor design, each compressor includes an individual nameplate along with a nameplate identifying the tandem compressors. On units that utilize the tandem reciprocating design, each

6 McQuay Cat 565-1 Introduction IntroductionQuality McQuay air handling equipment has been respected and regarded as high quality for nearly 60 years. McQuay has taken a major step in redefining the indoor air handler with the Vision air handler. Demands for improved indoor air quality, low sound, high operating efficiency and smaller mechanical McQuay Cat 251-1 5. Maverick I™—3 to 20 Tons [10.6 to 70.3 kW] Scroll compressors. • R-22 refrigerant • Provide maximum depend ability, efficiency and quiet operation. • Two refrigerant circuits on larger units provides redundancy for reliable cooling • Optional compressor low and high pressure safety switches.First, determine the type of equipment from the two categories shown below. The photos and diagrams will help you locate the model and serial numbers of your equipment, if they are not found on your original warranty or sales invoice. Split Systems. Two Model and Serial Tags identify Split System Equipment. Package Systems.Instagram:https://instagram. massive boobs expansionbarbely's restaurant newark mdweather in wildwood new jersey 10 daysdeana neese Models AGZ-E, AGZ-F, AMZ, EWYQ. Cool your building more efficiently and save money with the Trailblazer air-cooled scroll chiller. The Trailblazer is Daikin Applied's first available unit designed with R32 refrigerant, boasting a 33% reduced footprint and 10% reduced weight. Trailblazer chillers operate in off-design conditions 95% of the ...MODEL NOMENCLATURE Table 1: Unit Nameplate Model Number Identifier Model AHP = Air Cooled Heat Pump Nominal Capacity (tons) 090 = 7-1/2 120 = 10 Future Use Voltage/Phase P = 208-230/3/60 Q = 460/3/60 EER E = 10.1 Vintage AHP 090 A PEY Unit Nameplate McQuay Model Number CPLE090-3C AHP090APEY CPLE090-4C AHP090AQEY CPLE120-3C AHP120APEY CPLE120-4C ... publix coral gables flwordscapes level 1991 First, find the model number on the unit. It should be on a sticker or plate somewhere on the front or side of the AC. Once you have the model number, locate the first two digits. These digits will tell you the approximate tonnage of the unit. For example, if the model number starts with 24, the AC is approximately 2 tons.For example, if you see numbers like 18, 24, 30, etc., these may indicate the capacity in thousands of BTUs. We will explain below how to easily decode the tonnage of your AC from these numbers. 2. Check for a series of letters or digits. Some manufacturers include a series of letters or digits in the model number that represents the tonnage. tax commissioner columbus ga McQuay Air Conditioning plant with over 450,000 square feet of manufacturing space - located in Auburn, New York Horizontal (Ceiling) Water Source Heat Pumps - Sizes 007-070 (1/2 to 6 Tons) Model CRH (Standard Range: 55°F to 110°F) Model CRW (Extended Range/Geothermal: 25°F to 110°F) More than 40 years ago, McQuay designed the firstToday we get a little more familiar with the Carrier® Unit Model Number "38ARZ008---511" Commercial Air-Cooled Split System.. 38ARZ008---511. The "38AR" indicates that this unit is a Commercial Air-Cooled Condensing Unit. 38ARZ008---511. The "Z" stands for Single Circuit Scroll Compressor. 38ARZ008---511. The "008" tells us that this particular unit has a capacity of 7 tons.